By Greg Allan, tradesman and creator of Data First Coaching
Which Australian standards and codes does a window and door business work to?
A window and door installer in Australia works to the glazing provisions in the National Construction Code, the Australian Standard for glazing design AS 2047, and the safety glass standards AS 1288 and AS/NZS 2208 for doors, screens and glazed areas near floors, on top of whatever licence or registration the state or territory requires for the install itself. Which combination applies depends on the job: a sliding door replacement in an external wall is treated differently to a skylight, and a security screen is treated differently to a shower screen.
That is the short version. The detail below is general information, because the exact standard that applies changes with the glass type, the frame, the wall it sits in and the state the job is in.
Do you need a licence to install windows and doors?
Yes, in most of Australia, though the licence and when it kicks in differ by state. According to Fair Trading NSW, a licence or certificate is required to do glazing work in New South Wales, and a contractor licence is needed for residential glazing work above a dollar value in labour and materials, a figure best checked on that page because it changes. The qualification path it names is a Certificate III in Glass and Glazing.
In Queensland, the QBCC licenses glazing, glass and aluminium work, covering the fabrication and install of windows and doors, shopfronts, toughened glass assemblies and aluminium glazing systems, and it accepts mutual recognition applications from other states, territories and New Zealand. In Victoria, the Victorian Building Authority registers a domestic builder class limited to window and door replacement and install, covering removing the old unit, preparing the frame, positioning the new window or door, fitting flashing and testing the finished install.
For a window and door installer working across state lines, on a renovation near a border, or taking on a commercial shopfront, the registration that applies at home is not always the one that applies on site. Keeping the licence, the qualification and the renewal date against the job itself, rather than in a filing cabinet, is what a data first approach to compliance looks like for a window and door business. An AI agent, which is software that does a job the way you would, with your own wording and rules, can hold that record against every job and every state the crew works in, so nobody finds out a licence has lapsed partway through a measure visit.
What standards do the windows and doors themselves need to meet?
The window or door unit itself is expected to meet AS 2047 for resistance to water penetration when it sits in an external wall, under both the housing and the commercial volumes of the National Construction Code's glazing requirements and Part F1 on damp and weatherproofing. That standard covers the glass and the design testing of the unit, not the install.
The explanatory notes on the NCC's own glazing page are direct about this: AS 2047 applies to the selection of the glass only, and does not cover the install of the window or the framed glazed door, because the window system relies on the structural design of the frame to carry wind load, and on the perimeter frame, sealants and gaskets to keep water out. For a window and door installer, that is the gap between buying a compliant unit from the supplier and actually weatherproofing it once it goes in: the flashing, the sealant and the fit around the opening sit outside AS 2047 and inside the install itself.
What about safety glass in doors, screens and glazed areas?
Toughened and safety glass used in doors, security doors, screens and shower areas is expected to meet AS 1288 for selection and install, and AS/NZS 2208 for the safety glazing material itself, according to the NSW guidance on toughened glass. AS 1288 sets out where toughened or laminated glass is expected in human impact locations, and AS/NZS 2208 sets the standard the glass itself is tested and marked against.
A government technical guideline for non-residential building work, TG030 on glass panels, says every safety glazing panel on a project is expected to carry a legible mark showing it meets AS 1288 and is marked in line with AS/NZS 2208, with single and double glazed units marked differently. For a bifold or sliding door with large glass panels, or a security door with a glazed insert, that marking is the easy way to check compliance on site without pulling up a test certificate.
What is excluded from these standards?
A window and door installer does not need every job to meet AS 2047 design testing. According to Part F1 of the National Construction Code, glazed assemblies that are not in an external wall, skylights and roof lights, windows that are not in the vertical plane, sliding and swinging glazed doors without a frame, site-built or one-off architectural windows not design tested to AS 2047, and second-hand, re-used, recycled or heritage windows, do not need to meet that clause.
That distinction matters at quoting time. A standard aluminium or timber frame window replacement in an external wall sits squarely inside AS 2047 and the licence that goes with install. A heritage window being restored, or a one-off architectural piece built for a renovation, is handled differently, and the installer needs to know which job is which before the quote goes out, not after. AI agents that watch the job type, the glass and the frame against this list can flag a mismatch before the quote is sent, rather than after a compliance check fails on site.
This is general information, not legal, tax or employment advice. Check your own situation with the body named here or a qualified adviser.
Where can you check the current rules?
- Part F1 damp and weatherproofing (NCC): which glazed assemblies must meet AS 2047 and which are excluded.
- Glazing work licensing (Fair Trading NSW): the licence and qualification path for glazing work in New South Wales.
- Part 3.6 Glazing (NCC): how AS 2047 applies to glass selection and why install sits outside it.
- Toughened glass safety standards (NSW Government): AS 1288 and AS/NZS 2208 for safety glazing.
- Glass panel marking guideline TG030 (WA Government): how safety glass panels are expected to be marked.
- Glass, glazing and aluminium licensing (QBCC): licensing in Queensland and mutual recognition from other states and New Zealand.
- Domestic building work definitions (VBA Victoria): the registration class limited to window and door replacement.
How does Data First Coaching approach this?
Data First Coaching, built by Greg Allan, starts from the window and door installer's own job records rather than a memory of which licence, which standard and which supplier certificate applied to which job. The Trade Business Intelligence reads that job and compliance data alongside ten years of coaching trade businesses, so it can show where a compliance gap on paper is actually a gap in how a measure visit or a handover is recorded, not just a missing form. The how, the checklists and the agent build that carries this for a window and door business are worked through inside the Academy, with members, because the Trade Business Intelligence is powered by every member who joins it.